Flange & Foot Mount Motors Automatic Swing & Sliding Doors High Speed Motors Fire Door Motors Sectional Door Motors Direct Drive Motors Tube Motors Powered Blinds and Awnings Barrel Assembly Sliding Door Gear Safety Equipment Intercom Systems/Access Controls Gate & Barrier Automation Training Courses Garage Door Operators

Spider Auto Door Opener Launched at Ellard Limited

Spider Auto Door Opener Launched at Ellard Limited

The parameters of the controller can only be adjusted by the  SPIDER WEB. The spider web is a dual control unit, it works both as:

  1. A function selector
  2. Data adjuster

Spider Auto Door Opener Launched at Ellard LimitedSpider Auto Door Opener Launched at Ellard Limited

TWO WAY – The door opens by activating any installed opening control

EXIT ONLY – The external sensor is deactivated, all other opening controls remain active

ENTRY ONLY – The internal sensor is deactivated, all other opening controls remain active

DOOR OPEN – The door opens and remains open permanently

NIGHT LOCK – The door is closed and the sensors not active. The door may only be opened with the Emergency opening button

MANUAL – The door automatic mode is deactivated and the leaves can be moved manually, after changing mode “Manual” to other another mode the door will close automatically

Spider controller (Data Adjuster)

Press button “SET”  for more than 8 seconds, you will then be able to adjust the data

Spider Auto Door Opener Launched at Ellard Limited Spider Auto Door Opener Launched at Ellard Limited

Spider web (Data Adjuster)

Code no. Value range  Default value  Details 
P01 30-99 80 Opening speed
P02 30-99 65 Opening speed
P03 05-30 6 Buffer speed when opening
P04 05-30 10 Buffer Speed when closing
P05 20-50 30 Braking distance when opening
P06 10-50 30 Braking distance when closing                       * If value is in 10-20 you should adjust P02 and P04 to avoid door leaves hitting each other*
P07 01-03 2 Auto reverse force when opening
P08 01-03 2 Auto reverse force when opening
P09 01-03 2 Holding force-closed
P10 20%-80% 60% Partial opening
P11 00-60 6 Door hold time (0-60S)
P12 00-01 0 Aux lock type (00: lock with power, 01: lock without power)
P13 00-01 0 Battery monitoring (00: disabled, 01: lock without power)
P14 00-02 0 Battery mode (00: open, 01:closed 02: automatic)
P15 00-01 0 Fire alarm mode (00, open, 01: closed)
P16 00-01 1 Fire alarm equipment (00: NO, 01: NC)
P17 00-01 1 Photocell signal (00: NO, 01:NC)
P18 00-01 1 Opening direction (00: right opening, 01: left opening
P19 00-01 0 Door working mode (00: normal working, 01: toggle working
P20 00-01 0 Aux lock way (00: closed by remote or switch) 01: auto lock each time when closed)
P21 00-01 0 Inner threshold: Monitored (00: NO, 01: YES)
P22 00-01 0 Outer threshold: Monitored (00: NO, 01:YES)
P23 00-01 0 Left side screen: Monitored (00: NO, 01:YES)
P24 00-01 0 Right side screen: Monitored (00: NO, 01: YES)
P25 00-02 0 Working times (00: no limit, 01: 1000000, 02: 10000