Back

OUR PRODUCTS

Our Product Range Consists of:
Flange Motors Automatic Sliding Doors High Speed Motors Fire Door Motors Sectional Door Motors Direct Drive Motors Auto Swing Door Tube Motors Barrel Assembly Sliding Door Gear Traffic Barrier - Niuba Swing Gate Motors Sliding Gate Motors Residential Garage Door Motors Safety Equipment Intercom Systems/Access Controls Gate Automation Training Courses
Ellard > Products > Swing Gate Motors

Swing Gate Motors

Ellard are the sole UK and Ireland distributor for V2 swing gate motors. We offer a wide range of products including Underground, Hydraulic and electro – mechanical operators in either 23V or 24V configurations.

  • Description

    Swing Gate Range Includes:

    Features of the Swing Gate Range:

    • Integrated Starter- with transformer if required
    • Safety inputs
    • Auto learn feature for fast set up
    • Battery and solar power back ups available

    Ellard provide a range of Swing Gate Operators for use on gates up to 7m in length. Our range of gate automation is manufactured in Italy by V2, and our close working partnership is ideal to maintain both quality control and expert technical support that makes Ellard a great choice for your Gate Automation needs. All motors and controllers are compatible with the required safety equipment to make your installation safe, and to give you piece of mind that your installation is compliant with the latest laws.

    Ellard ltd are leading suppliers of swing gate automation systems. If you would like to find out more about our swing gate motors, then please get in touch with a member of our expert team.

  • Technical Specification

    Swing Gate Motor Specification

    Swing Gate Motors            
    AXIL            
    Features Units 22J001 22J002 22J003 22J005 22J010
    Maximum leaf length m 2,8 2,8 2,8 2,8 2,8
    Maximum leaf weight Kg 300 300 300 300 150
    Power supply V/Hz 230-50 230-50 230-50 24Vdc 24Vdc
    Idling current A 0,8 0,8 8,0 1,0 1,5
    Full load current A 1,1 1,1 1,1 6,5 12
    Maximum power W 230 230 230 - -
    Maximum travel mm 350 350 350 350 350
    Operating speed m/s 0,016 0,016 0,016 - -
    Opening time 0÷ 90° s 20 20 20 20 9
    Maximum thrust N 1700 1700 1700 1700 1700
    Working temperature °C -30 ÷ +55 -30 ÷ +55 -30 ÷ +55 -30 ÷ +55 -30 ÷ +55
    Protection degree IP 44 44 44 44 44
    Duty cycle % 35 35 35 60 60
    Weight Kg 7,5 7,5 7,5 7,5 7,5
                 
                 
    BINGO            
    Features Units 22B001 22B007 22B006 22B011  
    Maximum leaf length m 3,5 5 3,5 5  
    Maximum leaf weight Kg 400 500 350 400  
    Power supply V/Hz 230 - 50 230 - 50 24Vdc 24Vdc  
    Idling current A 2 2 1,8 1,8  
    Full load current A 3,2 3,2 5 5
    Maximum power W 480 480 - -  
    Maximum travel mm 365 485 365 485  
    Operating speed m/s 0,017 0.017 - -  
    Opening time 0÷ 90° s 18 24 18 24  
    Maximum thrust N 1800 1800 1800 1800  
    Working temperature °C -30 ÷ +60 -30 ÷ +60 -30 ÷ +60 -30 ÷ +60  
    Protection degree IP 34 34 34 34  
    Duty cycle % 30 30 80 80  
    Weight Kg 11 12 11 12  
                 
                 
    BLITZ            
    Features Units 22E001. 22E002.      
    Maximum leaf length m 3 3      
    Maximum leaf weight Kg 800 800      
    Power supply V/Hz 230/50 24Vdc      
    Full load current A 2,5 7,5      
    Maximum power W 575 -      
    Speed Rpm 1,6 1,4 ÷ 0,5      
    Torque Nm 340 320      
    Working temperature °C -30 ÷ +60 -30 ÷ +60      
    Protection degree IP 44 44      
    Duty cycle % 20 80      
    Weight Kg 14,6 14,6      
                 
                 
    Calypso            
    Features Units 22G001 22G003 22G014 22G015 22G016
    Maximum leaf length m 2,5 3 2,5 3 4
    maximum leaf weight Kg 400 500 300 400 500
    Power supply V/Hz 230 - 50 230 - 50 24Vdc 24Vdc 230 - 50
    Idling current A 0,8 0,8 0,5 0,5 0,8
    Full load current A 1,2 1,2 6 6 1,2
    Maximum power W 250 250 100 100 250
    Maximum travel mm 400 500 400 500 600
    Operating speed m/s 0,016 0,016 - - 0,016
    Opening time 0÷ 90° s 22 25 22 27 30
    Maximum thrust N 2300 2300 1500 1500 2300
    Working temperature °C -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50 -30 ÷ +50
    Protection degree IP 44 44 44 44 44
    Duty cycle % 30 30 90 90 90
    Weight Kg 6,5 6,8 6,3 6,6 7,1
                 
                 
    Ciclon            
    Features Units 22E009.        
    Maximum leaf length m 2,5        
    maximum leaf weight Kg 400        
    Power supply V/Hz 230 / 50        
    Normal absorption A 1        
    Normal power W 230        
    Speed Rpn 1,3        
    Torque Nm 220        
    Working temperature °C -20 ÷ +60        
    Protection degree IP 54        
    Duty cycle % 20        
    Weight Kg 13        
                 
                 
    Zariss            
    Features Units 22E006. 22E007. 22E005.    
    Maximum leaf length m 2,2 2,2 2,2    
    Maximum leaf weight Kg 250 250 250    
    Power supply V/Hz 230 - 50 24Vdc 230 - 50    
    Full load current A 0,4 3,5 -    
    Maximum power (2 motors) W - - 180    
    Speed Rpm 1,1 ÷ 1,65 1,1 ÷ 1,65 1,1 ÷ 1,65    
    Torque Nm 180 180 180    
    Working temperature °C -20 ÷ +55 -20 ÷ +55 -20 ÷ +55    
    Protection degree IP 44 44 44    
    Duty cycle % 80 80 80    
    Weight Kg 10 8 18    
    Maximum load on 24 vac accessories W 7 7 7    
                 
                 
    Vulcan            
    Features Units 22F003 22F005 22F008    
    Maximum leaf length m 3,5 3,5 3,5    
    Maximum leaf weight Kg 800 600 800    
    Power supply V/Hz 230 / 50 24Vdc 230 / 50    
    Full load current A 2,4 15 2,4    
    Maximum power W 550 - 550    
    Opening time (90°) s 17 15 ÷ 25 17    
    Maximum torque Nm 320 320 320    
    Working Temperature °C -20 ÷ +55 -20 ÷ +55 -20 ÷ +55    
    Protection degree IP 67 67 67    
    Duty cycle % 30 80 30    
    Weight kg 11 11,5 11    
                 
                 
    Lycos            
    Features Units 22D007 22D008      
    Maximum leaf length m 2,5 2,5      
    Maximum leaf weight Kg 300 300      
    Power supply V/Hz 230 / 50 230 / 50      
    Full load current A 0,7 0,7      
    Maximum power W 160 160      
    Maximum travel mm 265 265      
    Operating speed m/s 0,013 0,013      
    Opening time 0÷ 90° s 17 17      
    Maximum thrust N 3000 3000      
    Working temperature °C -30 ÷ +60 -30 ÷ +60      
    Protection degree IP 54 54      
    Duty cycle % 75 75      
    Weight Kg 7,5 7,5      
                 
                 
    Ursus            
    Features Units 22D002 22D003 22D005 22D004 22D006
    Maximum leaf length m 4 4 4 6 6
    maximum leaf weight Kg 700 700 700 700 700
    Power supply V/Hz 230 - 50 230 - 50 230 - 50 230 - 50 230 - 50
    Full load current A 1 1 1 1 1
    Maximum power W 230 230 230 230 230
    Maximum travel mm 265 265 265 400 400
    Opening speed m/s 0,01 0,01 0,01 0,01 0,01
    Opening time 0÷ 90° s 22 22 22 33 33
    Maximum thrust N 7000 7000 7000 7000 7000
    Working temperature °C -30 ÷ +90 -30 ÷ +90 -30 ÷ +90 -30 ÷ +90 -30 ÷ +90
    Protection degree IP 65 65 65 65 65
    Duty cycle % 100 100 100 100 100
    Weight Kg 9,5 9,5 9,5 11 11
  • Reviews

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    Security Code
    captcha
    Enter Code

  • FAQs

    • What industrial door motors do you sell?

      Here at Ellard ltd we specialise in supplying industrial door motors and supply a comprehensive range of motor types and models. This includes, direct drive, flange, foot mount, garage door and tubular motors. Our selection is vast, so for a comprehensive list of our products and specifications you can visit our dedicated pages or get in touch with our expert team.

    • Do your traffic barriers have obstacle detection?

      Yes, our Nubia traffic barrier has built in intelligent controllers which offer obstacle detection and built in lights to make them easy to see in the dark or in bad weather.

    • What are the benefits of direct drive motors?

      Direct drive motors remove the need to use an elaborate system of cogs. This means that the full power of the motor goes straight into the pulling mechanism, making it an extremely efficient motor. Without the extra mechanisms, it also has a very low sound output comparatively to other methods.

    • Why should I use a fire motor as part of my fire safety plan?

      Fire motors are often connected to your fire detection system and activate if fire is detected on your premises. They quickly and efficiently close helping to contain the fire and keep your employees/customers safe from the dangerous area. Government legislation requires that all fire doors must have an automatic function and all Ellard fire motors comply with the latest rules and regulations. All motors can be set to a Smoke Curtain mode, and our new Fire Door Control Panel has a panic circuit function to guarantee a means of escape.This allows you to re-open the shutter 3/4 then immediately re-close when fire alarm is still active.

    • Can I link specific access controls to my gate automation system?

      Yes, our gate automation systems can be linked to keypads, switches, intercom systems and key switches, dependant on your specifications or security requirements. Take a look at the range of controls and accessories available for gate automation.

    • Can I add extra features to my sectional door drives?

      Yes, we ensure that your sectional doors have easy wiring to add safety and access accessories.

    • What are the main applications for high speed motors?

      High speed motors are used for a wide range of purposes and can increase the efficiency of companies when time is of importance. Beverage, food, car and chemical factories often use high speed motors both to increase productivity and provide a security barrier. They can also be interlocked to create a airlock function

    • What size strips do you supply your sliding door gear track?

      Our track sections are cold rolled and in standard lengths of 2,000, 2,500 and 3,000mm and can be used for both side or top fixing. If you would like to learn more about our sliding door gear then please get in touch with our team.

    • Which motors are most commonly used for shutters and garage doors?

      Tubular motors are the most common place motor for roller garage doors and shutters. They provide a durable, fast and quiet solution for both light and heavy applications. Tubular motors can be plugged into the mains through our easy fit panel to give you low voltage at the key switch or are backed up with battery power.

    • Why should I use a fire motor as part of my fire safety plan?

      Fire motors are often connected to your fire detection system and activate if fire is detected on your premises. They quickly and efficiently close helping to contain the fire and keep your employees/customers safe from the dangerous area. Government legislation requires that all fire doors must have an automatic function and all Ellard fire motors comply with the latest rules and regulations. All motors can be set to a Smoke Curtain mode, and our new Fire Door Control Panel has a panic circuit function to guarantee a means of escape.This allows you to re-open the shutter 3/4 then immediately re-close when fire alarm is still active.